ÇöÀçÀ§Ä¡ : Home  > ÀÌ¿Â ÃøÁ¤±â ¹æ»ç¼±ÃøÁ¤±â UV PROCESS µ¥ÀÌÅͷΰŠ¹× ±â·Ï°è Àü±â ¹× Àü·ÂÃøÁ¤±â ±â»ó°üÃø±â ÃÊÁß°í°úÇб³À°Àåºñ ¾Ð·Â°è ¿È»óÄ«¸Þ¶ó ¿Â¶óÀεβ²ÃøÁ¤±â °æµµ°è Àû¿Ü¼±¿Âµµ°è,¿Âµµ°è ¼ÒÀ½Áøµ¿°è ¿Âµµ/¾Ð·Â/½Àµµ/Àü±â ±³Á¤±â ³ëÁ¡,¿Â½Àµµ,¼öºÐ°è UV°ü·ÃÁ¦Ç° ȸÀü¼öÃøÁ¤±â Lutron1 Á¦Ç° (Àü±â, ÀüÀÚ °èÃø±â) ÀÎÀå¾ÐÃà ÅÙ¼Ç,ÅäÅ© ½ÃÇè±â ÃÊÀ½ÆÄµÎ²² ÃøÁ¤±â, Ž»ó±â ÄÚÆÃµµ±Ý µÎ²²ÃøÁ¤±â dz¼Ódz·®°è À¯·®°è ¿·ù°è, ¿·®°è ±¼Àý°è, Æí±¤°è ÀüÀÚÀú¿ï °¡½ºÃøÁ¤±â ºÐÁø ÀÔÀÚ¼ö ÃøÁ¤±â ¸éÀúÇ× ÃøÁ¤±â »öÂ÷°è, ±¤ÅÃ°è Æ¯¼öÄ«¸Þ¶ó(°í¼Ó °íÇØ»ó) ºÐ±¤±¤µµ°è (Spectrophotometer) ·¹ÀÌÀú Ç¥¸éÁ¶µµ°è Á¤Àü±â, ÀüÀÚÆÄ ÃøÁ¤±â ¿¬¼ÒÈ¿À²ÃøÁ¤±â ¼öÁú½ÃÇè±â ¹°¸®·® ¹°¼º ÃøÁ¤±â ½ë¼ ·¹º§°è (Level) Àü±â°èÃø±â, ÀüÀÚ°èÃø±â Lutron2 Á¦Ç° (¼öÁú,ȸÀü¼ö,¼ÒÀ½Áøµ¿, ±¤·®, ¿Â½Àµµ, dz¼Ó) Testo (¿Âµµ, ½Àµµ, dz¼Ó, ¾Ð·Â, ¼ÒÀ½, RPM, °¡½º) °ø±¸°èÃø±â(Mitutoyo) DAVIS (»óǰ 25000°³) ºñÆÄ±« ½ÃÇè±â Gardner DNA Fluke Á¦Ç° ¿Âµµ°è Thermometer ºñµð¿À °Ë»ç Çö¹Ì°æ ÀÌÈÇбâ±â ³ó¾÷¿ë ½ÃÇè±â ±¹»ê Á¦ÀÛ±â±â ¹ßÀü±â, ¹èÅ͸® ¹× ÃæÀü±â ÀÇ·á¿ë °èÃø±â ¼Ö¶ó¼¿ (žçÀüÁö), dz·Â, ¼Ò¼ö·Â, ¿¬·áÀüÁö X-Ray °ø±¸°èÃø±â (Fowler) ¿ëÁ¢±â ¹ÝµµÃ¼ Àåºñ À¯¸® ÃøÁ¤±â CRM (°í°´°ü¸®¿ë) ¼ÒÇÁÆ®¿þ¾î ESCO (¿¡½ºÄÚ) µî·Ï Àåºñ ¹«¼±ÃøÁ¤±â ½ÅÁ¾Ç÷ç Àåºñ µ¥ÀÌÅͼöÁý½Ã½ºÅÛ (Data Acquisition) optris(¿ÉÆ®¸®½º) ¹ýÁ¤½ÃÇèÀåºñ (µî·ÏÇã°¡ Àåºñ) ÁÖ¹®»óǰ Ưº°»óǰ LED ·¥ÇÁ ¹èÅ͸® 3D Printer Àå±âÀç°í ƯÆÇ (2020³â2¿ù) HOTIK (XINTEST) Á¦Ç° RIGOL Á¦Ç° (Å×½ºÆ®½Ã½ºÅÛ) KEM Á¦Ç° (ºÐ¼®Àåºñ) Ư°¡ÆÇ¸Å»óǰ ±â·ùÃøÁ¤±â ¹× dzµ¿½ÇÇèÀåÄ¡ Ç¥¸é¿°ºÐÃøÁ¤±â ³²ÀÚÀÇ ¹°°Ç(RC) ¿È»óÄ«¸Þ¶ó (Áø´Ü¿ë) MYWATT ½º¸¶Æ® Àü·Â ÃøÁ¤·Î°Å TESTO Àå±âÀç°í (ƯÆÇ) TES Àå±âÀç°í (ƯÆÇ) ÇöÀç ºÐ·ù   > Electronic ÀüÀÚ°èÃø±â Àü±â°èÃø±â Electrical À½¼º µ¥ÀÌÅÍ Voice/Data °øÁ¤Á¦¾î process & Control ±³Á¤±â Calibrators µ¥ÀÌÅͷΰÅ, ±â·Ï°è  Datalogger, Recorder ¿Âµµ Temperature ½Àµµ/³ëÁ¡/¼öºÐ Humidity/Dewpoint/Moisture General Test Scales ÀüÀÚ Àú¿ï Data Acquisition/Recorders µ¥ÀÌÅÍ ¼öÁý ¹× ±â·Ï°è Panel Meters Safety ¾ÈÀü¿ë Á¦Ç° Air Velocity / Manometer dz¼Ó ¹× ´ë±â¾Ð ÃøÁ¤±â Flow À¯·®°è Pressure ¾Ð·Â°è, Áø°ø°è Water Quality ¼öÁú ½ÃÇè±â Level Speed  ȸÀü¼ö ÃøÁ¤±â Physical Dimension °ø±¸ ¹× ¹°¸® ½ÃÇè±â Vibration Leak Detection ´©¼³ ŽÁö±â Weather ±â»ó °üÃø±â Light Á¶µµ ÃøÁ¤±â Sound Shipping Cases Ahlborn Á¦Ç° ÇöÀç ºÐ·ù   > Transmitters and Switches Analog Gauges Miscellaneous Digital Gauges Handheld Pressure Pumps ÇöÀç ºÐ·ù 
DW6551 Wet/Wet Differential Pressure Transmitter 
            
	 
     
     
     
 
This Wet/Wet Differential Pressure Transmitter converts a positive.Refrigeration & HVAC Equipment   
This Wet/Wet Differential Pressure Transmitter converts a positive or a positive differential pressure measurement into a standard 4-20 mA output signal. Designed for use as a wet/wet differential pressure transmitter, units can be used to measure gas or liquid pressures compatible with 316/316L stainless steel wetted parts. With an accuracy of ¡¾0.5% FS, the Series 655 Pressure Transmitter can measure 5.0 inches w.c.d (1.24 kPa), with working pressures up to a maximum 100 psi (6.89 bar). CAUTION: Do not exceed specified supply voltage ratings. Permanent damage not covered by warranty will result. This device is not designed for 120 or 240 volt AC operation. Use only 16 to 35 Vdc.  
    
Features   
  
Wet/Wet Low Differential Pressure – 0-5" w.c.  
Withstands High Pressure – 100 PSI Maximum Working Pressure  
Excellent Wetted Materials – 316/316L Stainless Steel  
External Span And Zero Adjustments – +/- 10% of span  
Highly Accurate – +/-0.5% Full Scale     
    
Applications   
  
Refrigeration & HVAC Equipment  
Chill Water Line Pump Monitoring  
Water Filter Monitoring  
Process Control     
    
   
SPECIFICATIONS  
Service 
 
Compatible, non-combustible gases & liquids  
Wetted Materials  
Types 316, 316L SS  
Accuracy  
+/-0.5% F.S. (Includes linearity, hysteresis & repeatability)  
Stability  
+ 1% F.S./yr  
Temperature Limits  
40 to 120¡ÆF (4.44 to 48.9¡ÆC)  
Pressure Limits  
100 psi (6.89 bar) continuous; 500 psi (34.5 bar) burst  
Thermal Effect  
0.025% F.S./¨ùF (0.045% F.S./¡ÆC)  
Power Requirements   
16-35 VDC (2 wire)  
Output Signal 4 to 20 mA  
Zero & Span Adjustments  
Accessible Potentiometers  
¡¾10% of span  
Loop Resistance  
DC; 0-1250 ohms maximum  
Current Consumption  
DC; 38 mA max  
Electrical Connections  
3 position plastic terminal block  
Process Connections  
1/4" female NPT  
Enclosure Rating  
Designed to meet NEMA 4X  
Mounting Orientation  
Not position sensitive  
Weight  
1 lb., 11.7 oz. (785 g)   
 
CAT NO.  
 
MODEL  
 
DEscRIPTION  
 
AVAIL  
 
PRICE     
DW6551  
   
655-1  
   
Wet/Wet Differential Pressure Transmitter  
   
Yes  
   
1,293,840    
 
 
 
    
    »ç¿ëÈı⠸®½ºÆ® 
    
         
         
     
    
        
            Á¦¸ñ 
            Æò°¡ 
         
     
    
    
            ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù. 
            »ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. 
              
    
    * ÀÌ »óǰÀ» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ 
    
    
	
     
     
     
	 
 
 
	
	»óǰ¹®ÀÇ ¸®½ºÆ® 
	
		 
		 
	 
	
		
	        Á¦¸ñ 
		    ´äº¯ 
	     
	 
	
	
		
		ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù. 
	    ±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. 
     	 
	
	* ÀÌ »óǰ¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
	¹®ÀÇÇϱâ 
	
	
	
	 
	 
	 
	 
 
 
ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù.