ÇöÀçÀ§Ä¡ : Home  > ÀÌ¿Â ÃøÁ¤±â ¹æ»ç¼±ÃøÁ¤±â UV PROCESS µ¥ÀÌÅͷΰŠ¹× ±â·Ï°è Àü±â ¹× Àü·ÂÃøÁ¤±â ±â»ó°üÃø±â ÃÊÁß°í°úÇб³À°Àåºñ ¾Ð·Â°è ¿È»óÄ«¸Þ¶ó ¿Â¶óÀεβ²ÃøÁ¤±â °æµµ°è Àû¿Ü¼±¿Âµµ°è,¿Âµµ°è ¼ÒÀ½Áøµ¿°è ¿Âµµ/¾Ð·Â/½Àµµ/Àü±â ±³Á¤±â ³ëÁ¡,¿Â½Àµµ,¼öºÐ°è UV°ü·ÃÁ¦Ç° ȸÀü¼öÃøÁ¤±â Lutron1 Á¦Ç° (Àü±â, ÀüÀÚ °èÃø±â) ÀÎÀå¾ÐÃà ÅÙ¼Ç,ÅäÅ© ½ÃÇè±â ÃÊÀ½ÆÄµÎ²² ÃøÁ¤±â, Ž»ó±â ÄÚÆÃµµ±Ý µÎ²²ÃøÁ¤±â dz¼Ódz·®°è À¯·®°è ¿·ù°è, ¿·®°è ±¼Àý°è, Æí±¤°è ÀüÀÚÀú¿ï °¡½ºÃøÁ¤±â ºÐÁø ÀÔÀÚ¼ö ÃøÁ¤±â ¸éÀúÇ× ÃøÁ¤±â »öÂ÷°è, ±¤ÅÃ°è Æ¯¼öÄ«¸Þ¶ó(°í¼Ó °íÇØ»ó) ºÐ±¤±¤µµ°è (Spectrophotometer) ·¹ÀÌÀú Ç¥¸éÁ¶µµ°è Á¤Àü±â, ÀüÀÚÆÄ ÃøÁ¤±â ¿¬¼ÒÈ¿À²ÃøÁ¤±â ¼öÁú½ÃÇè±â ¹°¸®·® ¹°¼º ÃøÁ¤±â ½ë¼ ·¹º§°è (Level) Àü±â°èÃø±â, ÀüÀÚ°èÃø±â Lutron2 Á¦Ç° (¼öÁú,ȸÀü¼ö,¼ÒÀ½Áøµ¿, ±¤·®, ¿Â½Àµµ, dz¼Ó) Testo (¿Âµµ, ½Àµµ, dz¼Ó, ¾Ð·Â, ¼ÒÀ½, RPM, °¡½º) °ø±¸°èÃø±â(Mitutoyo) DAVIS (»óǰ 25000°³) ºñÆÄ±« ½ÃÇè±â Gardner DNA Fluke Á¦Ç° ¿Âµµ°è Thermometer ºñµð¿À °Ë»ç Çö¹Ì°æ ÀÌÈÇбâ±â ³ó¾÷¿ë ½ÃÇè±â ±¹»ê Á¦ÀÛ±â±â ¹ßÀü±â, ¹èÅ͸® ¹× ÃæÀü±â ÀÇ·á¿ë °èÃø±â ¼Ö¶ó¼¿ (žçÀüÁö), dz·Â, ¼Ò¼ö·Â, ¿¬·áÀüÁö X-Ray °ø±¸°èÃø±â (Fowler) ¿ëÁ¢±â ¹ÝµµÃ¼ Àåºñ À¯¸® ÃøÁ¤±â CRM (°í°´°ü¸®¿ë) ¼ÒÇÁÆ®¿þ¾î ESCO (¿¡½ºÄÚ) µî·Ï Àåºñ ¹«¼±ÃøÁ¤±â ½ÅÁ¾Ç÷ç Àåºñ µ¥ÀÌÅͼöÁý½Ã½ºÅÛ (Data Acquisition) optris(¿ÉÆ®¸®½º) ¹ýÁ¤½ÃÇèÀåºñ (µî·ÏÇã°¡ Àåºñ) ÁÖ¹®»óǰ Ưº°»óǰ LED ·¥ÇÁ ¹èÅ͸® 3D Printer Àå±âÀç°í ƯÆÇ (2020³â2¿ù) HOTIK (XINTEST) Á¦Ç° RIGOL Á¦Ç° (Å×½ºÆ®½Ã½ºÅÛ) KEM Á¦Ç° (ºÐ¼®Àåºñ) Ư°¡ÆÇ¸Å»óǰ ±â·ùÃøÁ¤±â ¹× dzµ¿½ÇÇèÀåÄ¡ Ç¥¸é¿°ºÐÃøÁ¤±â ³²ÀÚÀÇ ¹°°Ç(RC) ¿È»óÄ«¸Þ¶ó (Áø´Ü¿ë) MYWATT ½º¸¶Æ® Àü·Â ÃøÁ¤·Î°Å TESTO Àå±âÀç°í (ƯÆÇ) TES Àå±âÀç°í (ƯÆÇ) ÇöÀç ºÐ·ù   > Electronic ÀüÀÚ°èÃø±â Àü±â°èÃø±â Electrical À½¼º µ¥ÀÌÅÍ Voice/Data °øÁ¤Á¦¾î process & Control ±³Á¤±â Calibrators µ¥ÀÌÅͷΰÅ, ±â·Ï°è  Datalogger, Recorder ¿Âµµ Temperature ½Àµµ/³ëÁ¡/¼öºÐ Humidity/Dewpoint/Moisture General Test Scales ÀüÀÚ Àú¿ï Data Acquisition/Recorders µ¥ÀÌÅÍ ¼öÁý ¹× ±â·Ï°è Panel Meters Safety ¾ÈÀü¿ë Á¦Ç° Air Velocity / Manometer dz¼Ó ¹× ´ë±â¾Ð ÃøÁ¤±â Flow À¯·®°è Pressure ¾Ð·Â°è, Áø°ø°è Water Quality ¼öÁú ½ÃÇè±â Level Speed  ȸÀü¼ö ÃøÁ¤±â Physical Dimension °ø±¸ ¹× ¹°¸® ½ÃÇè±â Vibration Leak Detection ´©¼³ ŽÁö±â Weather ±â»ó °üÃø±â Light Á¶µµ ÃøÁ¤±â Sound Shipping Cases Ahlborn Á¦Ç° ÇöÀç ºÐ·ù   > Gas Detection Particulate Monitors Heat Stress/Strain Radiation Gas Analyzers Air Quality ÇöÀç ºÐ·ù 
UE50 Combustion Analyzer 
            
	 
     
     
     
 
The UE50 and UE75 will enable HVAC professionals to accurately test   
The UE50 and UE75 will enable HVAC professionals to accurately test and service all residential combustion appliances. The mutlimeter style rotary selector, allows the technician to easily choose combustion parameters allowing for quick measuring of flue temperature or oxygen and fast calculations of carbon dioxide, gross/net efficiency, or excess air. For technicians who are required to diagnose and repair heating equipment, the UE75 provides the added benefits of measuring Carbon Monoxide and calculating CO air free. Both analyzers have an extra large backlit LCD display that shows two parameters at one time. A protective ruggedize boot with an integral magnet allows for hands-free readings and provides the kind of durability expected.  
    
Features   
  
Easy multimeter style rotary selector  
Measures flue temperature and oxygen  
Calculates carbon dioxide, gross/net efficiency, and excess air  
Reads pre-programmed fuels natural gas, light oil, propane, butane, & LPG  
Infrared printer port allows for printing test results to an optional printer with date and time  
Large back-lit LCD, 2 line display  
Protected boot with an integral magnet  
Three year limited warranty with two years on sensor     
    
   
SPECIFICATIONS  
Parameter 
 
Resolution  
Accuracy  
Range  
Flue Temperature  
1¡ÆF/¡ÆC  
¡¾5¡ÆF (2¡ÆC) ¡¾0.3% reading  
32-1112¡ÆF (0-600¡ÆC)  
Oxygen  
0.1%  
¡¾0.2%*1  
0-21%  
Carbon Monoxide (UE75 Only)  
1ppm  
¡¾10ppm<100ppm*1 ¡¾5% of reading  
0-2000ppm (4000ppm max for 15 mins.)  
Carbon Dioxide*2  
0.1%  
¡¾0.3% reading  
0-30%  
Efficiency*2  
0.1%  
¡¾1.0 reading  
0-99.9%  
Excess Air*2  
0.1%  
¡¾0.2%  
0-250%  
Pre-programmed Fuels Natural Gas, Light Oil, Propane, Butane, LPG  
Weight  
2.2lb (1kg)  
Handset  
8" (200mm) x 2" (45mm) x 3.5" (90mm)  
Probe  
L 12" (300mm) x Dia 0.25" (6mm) with 8" (200mm) long stainless steel shaft, type K thermocouple and 9ft (3m) long neoprene hose  
Ambient Operating Range  
32-104¡ÆF (0¡ÆC to 40¡ÆC) 10% to 90% RH non-condensing  
Battery Life  
Standard "AA" (x4) >8 hours continuous use  
*1 Using dry gases at STP  
*2 Calculated   
 
CAT NO.  
 
MODEL  
 
DEscRIPTION  
 
AVAIL  
 
PRICE    
UE50  
   
C50  
   
Combustion Analyzer  
   
Yes  
   
861,840    
UE75  
   
C75  
   
Combustion Analyzer  
   
Yes  
   
1,079,978    
 
 
 
    
    »ç¿ëÈı⠸®½ºÆ® 
    
         
         
     
    
        
            Á¦¸ñ 
            Æò°¡ 
         
     
    
    
            ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù. 
            »ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. 
              
    
    * ÀÌ »óǰÀ» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ 
    
    
	
     
     
     
	 
 
 
	
	»óǰ¹®ÀÇ ¸®½ºÆ® 
	
		 
		 
	 
	
		
	        Á¦¸ñ 
		    ´äº¯ 
	     
	 
	
	
		
		ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù. 
	    ±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. 
     	 
	
	* ÀÌ »óǰ¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
	¹®ÀÇÇϱâ 
	
	
	
	 
	 
	 
	 
 
 
ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù.