AE212501 Power Quality Logger
            
	
    
    
    
 | 
| Portable, compact unit – plugs into standard US 120V outlets, Simple operation: Plug in, Record etc. | 
| 
 Features   |  
- Portable, compact unit – plugs into standard US 120V outlets 
 - Simple operation: Plug in, Record, Download and Read 
 - Measures & stores electrical parameters: V, A, Hz and more 
 - Measures and stores power parameters: W, VA, Var, Demand, Peak Demand and more 
 - Measures and stores power quality parameters: Harmonics, THD (rms and fundamental), K-Factor & more 
 - Automatically captures worst-case Surge, Sag & THD waveforms for voltage & current 
 - Stores 100 worst case surge & sag events including time, date & duration 
 - High accuracy & resolution: 128 samples/cycle, 16 bit resolution 
 - LEDs indicate mode of operation 
 - Records up to 12 data channels 
 - Powered from voltage input channel 
 - Battery backup data integrity during power outages for up to 1 year. Configuration in non-volatile memory 
 - Optically isolated RS-232 output for direct connection to a PC 
 - EN 1010, 150V, Cat. III 
 - Includes DataView¢ç Lite Analysis and Reporting Software DataView¢ç Lite and Professional Data Analysis & Reporting Software 
   |  
|   |   
| 
 Software Features   |  
- Display and analyze data on your PC 
 - Configure all data logger functions and parameters from your PC including sample rate, recording length, channel configuration & more 
 - Customize frames, templates & reports to your exact needs 
 - Display real time data on your PC & download previously recorded data 
 - Create & store a complete library of configurations that can be uploaded to the logger as needed 
 - Zoom in and out and pan through sections of the graph to analyze the data 
 - Display waveforms, trend graphs, harmonic spectrums and text summaries 
 - Display surge and sag events in high-resolution waveforms and as tabular listings 
   |  
|   |    |   SPECIFICATIONS 
| 
 Models  | 
 AE212501  | 
 AE212502  | 
 AE212503  | 
 AE212504  |  
| (Memory) | 
 (128KB)  | 
 (1MB)  | 
 (128KB)  | 
 (1MB)  |  
| Electrical Specifications |  
| Measurements | 
 True RMS measurement. 128 samples are simultaneously taken for voltage and current channel  |  
| Voltage |  
| Range | 
 0 to 140V  |  
| Resolution | 
 0.1V  |  
| Accuracy | 
 ¡¾(0.3% of Reading + 0.3V)  |  
| Current |  
| Range | 
 0 to 15A (70A peak maximum)  |  
| Resolution | 
 0.01A  |  
| Accuracy | 
 ¡¾(0.5% of Reading + 0.03A) @ 0.75A to 15A ¡¾0.30A @ < 0.75A  |  
| Frequency (Hz) |  
| Range | 
 45 to 65Hz  |  
| Resolution | 
 0.01Hz  |  
| Accuracy | 
 0.1Hz  |  
| Harmonics |  
| Range | 
 Up to 50th for both Voltage & Current  |  
| Resolution | 
 0.1V for Voltage & 0.1A for Current  |  
| Power - Watt/ VA/Var |  
| Range | 
 0 to 2.1K Watt or VA or Var  |  
| Resolution | 
 0.1W, 0.1VA, 0.1Var  |  
| Accuracy | 
 ¡¾(2.0% of Reading + 4x), where x is Watt or VA or Var  |  
| Power & Power Factor |  
| Resolution | 
 0.01  |  
| Accuracy | 
 ¡¾0.03% @ PF/DPF = 1  |  
| Programmable Parameters |  
|   | 
 V, A, Hz, Odd & Even Harmonics( V & A), W, VA, Var, THD (V & A), PF, DF, K-Factor  |  
| Demand | 
 VA, W (10/15/30 minutes or user-definable)  |  
| Peak Demand | 
 Over demand period  |  
| Voltage Sag/Surge | 
 User-definable magnitude  |  
| Input |  
| Input Channels | 
 1 Voltage/1 Current  |  
| Sample Rate | 
 128 per cycle per channel  |  
| Recording |  
| Storage Rate | 
 125ms to 7 days  |  
| Recording Session Length | 
 15 minutes to 8 weeks (user programmable)  |  
| Total Memory | 
 128KB  | 
 1MB  | 
 128KB  | 
 1MB  |  
| Date and Time | 
 MM/DD/YY hh/mm/ss.sss  |  
| 
 Surge & Sag and THD Waveform Storage (worst case)  | 
 5 THD Waveform  | 
 20 THD Waveform  | 
 5 THD Waveform  | 
 20 THD Waveform  |    
| CAT NO. | 
  | 
MODEL | 
  | 
DEscRIPTION | 
  | 
AVAIL | 
  | 
PRICE |   
| AE212501 | 
  | 
PQL 100 | 
  | 
Power Quality Logger (128KB storage) | 
  | 
Yes | 
  | 
1,717,200  |   
| AE212502 | 
  | 
PQL 120 | 
  | 
Power Quality Logger (128KB storage) | 
  | 
Yes | 
  | 
1,717,200  |   
| AE212503 | 
  | 
PQL 100 | 
  | 
Power Quality Logger (w/optional 1MB storage) | 
  | 
Yes | 
  | 
1,933,200  |   
| AE212504 | 
  | 
PQL 120 | 
  | 
Power Quality Logger (w/optional 1MB storage) | 
  | 
Yes | 
  | 
1,933,200  |   
| AE211902 | 
  | 
¡¡ | 
¡¡ | 
OPTIONAL Soft Carrying Case FOR Power Quality Loggers | 
  | 
Yes | 
  | 
32,400  |   
 |  | 
 
    
    »ç¿ëÈı⠸®½ºÆ®
    
        
        
    
    
        
            | Á¦¸ñ | 
            Æò°¡ | 
        
    
    
    
            ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù. 
            »ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. | 
        
    
    
    * ÀÌ »óǰÀ» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ
    
    
	
 
	
	»óǰ¹®ÀÇ ¸®½ºÆ®
	
		
		
	
	
		
	        | Á¦¸ñ | 
		    ´äº¯ | 
	    
	
	
	
		
		ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù. 
	    ±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. | 
    
	
	
	* ÀÌ »óǰ¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
	¹®ÀÇÇϱâ
	
	
	
 
 | 
| 
ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù. |