ÇöÀçÀ§Ä¡ : Home >  >  > 
AE211781 AC HIPOT TESTER
            
	
    
    
    
 | 
| AC Hipot programmable to 5kV@20mA, DC Hipot programmable to [email protected] | 
| 
 Programmable Digital Electrical Safety Testers   |  
- AC Hipot programmable to 5kV@20mA 
 - DC Hipot programmable to [email protected] 
 - Continuity measurement @ 100mA 
 - Insulation Resistance to 9900M¥Ø @ 500Vdc and 1000Vdc 
 - ARC current detection with programmable limits 
 - Programmable ramp and dwell times, output voltages and trip limits 
 - Selectable AC test frequency 50Hz and 60Hz 
 - Trip current setting without loads 
 - Automatic testing — store up to 6 test programs 
 - Line and load regulation for linear output voltage 
 - Highly visible warning light indicator for HV output 
 - Pass and fail lights with adjustable buzzer 
 - Program lock-out feature to prevent user error or program changes 
   |  
|   |    |   SPECIFICATIONS 
| 
 Model  | 
 AE211781  | 
 AE211782  | 
 AE211783  | 
 AE211784  |  
| AC Hipot | 
    |  
| Voltage Range | 
 100V to 5000Vac (5kV)  |  
| Voltage Step Resolution | 
 5V  |  
| Voltage Regulation | 
 ¡¾1% of Reading ¡¾ 5cts  |  
| Accuracy | 
 ¡¾1% of Reading ¡¾ 5cts (>500V)  |  
| Frequency | 
 50Hz or 60Hz (programmable)  |  
| Trip Current | 
 0.10mA to 20mA in 0.01mA steps  |  
| Max Current Output | 
 20mA @ 5kV  |  
| Accuracy | 
 ¡¾1% of Reading ¡¾ 5cts  |  
| Ramp and Dwell Time | 
 0.000s to 999.9s  |  
| DC Hipot | 
    |  
| Voltage Range | 
 —  | 
 —  | 
 100V to 6000Vdc (6kV)  |  
| Voltage Step Resolution | 
 —  | 
 —  | 
 5V  |  
| Voltage Regulation | 
 —  | 
 —  | 
 ¡¾1% of Reading ¡¾ 5cts  |  
| Accuracy | 
 —  | 
 —  | 
 ¡¾1% of Reading ¡¾ 5cts  |  
| Trip Current | 
 —   | 
 —   | 
 0.10mA to 7.50mA in 0.01mA steps  |  
| Max Current Output | 
 7.5mA @ 6kVdc  |  
| Accuracy | 
 ¡¾1% of Reading ¡¾ 5cts  |  
| Ramp and Dwell Time | 
 0.000s to 999.9s  |    
| 
 MODEL  | 
 AE211781  | 
 AE211782  | 
 AE211783  | 
 AE211784  |  
| Insulation Resistance (IR) |  
| DC Test Voltage | 
 —  | 
 500V & 1000V  | 
 —  | 
 500V & 1000V  |  
| Measurement Range | 
 —  | 
 1 to 9900M¥Ø  | 
 —  | 
 1 to 9900M¥Ø  |  
| Accuracy | 
 —  | 
 5% (1 to 500M¥Ø) 10% (500 to 2000M¥Ø)  | 
 —  | 
 5% (1 to 500M¥Ø) 10% (500 to 2000M¥Ø)  |  
| 
    | 
    |  
| 
    | 
    |  
| Test Time | 
 —  | 
 0.000s to 999.9s  | 
 —  | 
 0.000s to 999.9s  |  
| 
    | 
    |  
| Continuity Check |  
| Resistance Range | 
 0.001¥Ø to 1.500¥Ø  |  
| Test Current | 
 100mA (0.1A)  |  
| Accuracy | 
 0.1¥Ø @ 1¥Ø  |  
| ARC Detection | 
 Selectable in 2mA steps from 2 to 20mA  |    
| CAT NO. | 
  | 
MODEL | 
  | 
DEscRIPTION | 
  | 
AVAIL | 
  | 
PRICE |   
| AE211781 | 
  | 
H70 | 
  | 
AC HIPOT TESTER | 
  | 
Yes | 
  | 
3,013,200  |   
| AE211782 | 
  | 
H115 | 
  | 
AC HIPOT AND INSULATION RESISTANCE TESTER | 
  | 
Yes | 
  | 
3,661,200  |   
| AE211783 | 
  | 
H210 | 
  | 
AC/DC HIPOT TESTER | 
  | 
Yes | 
  | 
3,877,200  |   
| AE211784 | 
  | 
H215 | 
  | 
AC/DC HIPOT AND INSULATION RESISTANCE TESTER | 
  | 
Yes | 
  | 
4,525,200  |   
| AE211788 | 
  | 
SP02 | 
  | 
OPTIONAL HV Test Pistol Model SP02 FOR Hipot Testers | 
  | 
Yes | 
  | 
328,320  |   
| AE211789 | 
  | 
¡¡ | 
¡¡ | 
OPTIONAL HV Test lead 9 ft. (unterminated, 3m) FOR Hipot Testers | 
  | 
Yes | 
  | 
105,840  |    |  | 
 
    
    »ç¿ëÈı⠸®½ºÆ®
    
        
        
    
    
        
            | Á¦¸ñ | 
            Æò°¡ | 
        
    
    
    
            ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù. 
            »ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. | 
        
    
    
    * ÀÌ »óǰÀ» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ
    
    
	
 
	
	»óǰ¹®ÀÇ ¸®½ºÆ®
	
		
		
	
	
		
	        | Á¦¸ñ | 
		    ´äº¯ | 
	    
	
	
	
		
		ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù. 
	    ±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. | 
    
	
	
	* ÀÌ »óǰ¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
	¹®ÀÇÇϱâ
	
	
	
 
 | 
| 
ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù. |