|  ¡Ü Probe 
        tube with heated miniature thermistor for flow
 measurement and precision NTC resistance for measuring the ambient temperature 
        and automatic compensation.
 ¡Ü Evaluation 
        electronics are located in a separate sensor transmitter module.
 ¡Ü High 
        accuracy as a result of integrated temperature
 compensation and individual calibration in wind tunnel, with laser Doppler 
        anemometer as reference system.
 ¡Ü Response 
        time only 2s for smoothing the measured value indicated, optionally without 
        smoothing with 100ms response time.
 ¡Ü Suitable 
        for measuring small flow velocities in gaseous substances, particularly 
        for control systems and monitoring.
 ¡Ü Typical 
        applications include comfort index measurements, HEVAC applications, environmental 
        technology, clean room technology and process measuring and control technology.
 
 
 ¢Æ A special connector cable allows to connect the flow
 sensors to all ALMEMO¢ç multi-purpose devices, data
 loggers and data acquisition systems. For volume flow
 rate measurements the cross section of the ventilating
 shaft can be easily entered into ALMEMO¢ç devices. A
 problem-free averaging is then possible.
 
 
 
 
         
          | Types (incl. clamping holder and ALMEMO¢ç connecting cable 1.5m long):
 |   
          | Unidirectional (sensitive in one direction) with protected measuring tip
 |   
          | FVA605TA1 | Measuring range 0 to 1m/s |   
          | FVA605TA5 | Measuring range 0 to 5m/s |   
          | Omnidirectional (direction-independent, 
            symmetrical ball tip) with protecting cage (¨ª110mm) including carry-case |   
          | FVA605TA1O | Measuring range 0 to 1m/s |   
          | FVA605TA5O | Measuring range 0 to 5m/s |  | 
         
          | Technical Data: |   
          | Electronics Box with Sensor |   
          | Measuring range: FV A605 TA1(O)
 FV A605 TA5(O)
 | 0.01 to 1m/s 0.15 to 5m/s
 |   
          | Resolution: FV A605 TA1(O)
 FV A605 TA5(O)
 | 0.001m/s 0.01m/s
 |   
          | Accuracy: FV A605 TA1(O)
 
 FV A605 TA5(O)
 | ¡¾1.0% of final value and
 ¡¾1.5% of meas. value
 ¡¾0.5% of final value
 ¡¾1.5% of meas. value
 |   
          | Nominal conditions: | 22¡ÆC, 960hPa |   
          | Automatic temperature compensation:
 | effective in range 0 to 40¡Æ |   
          | Temperature influence: | ¡¾0.5% of fin. value/¡ÆC |   
          | Sensor |   
          | Head size: | ¨ª 8mm |   
          | Shaft: | ¨ª 15mm |   
          | Operative range: | 0 to 40¡ÆC |   
          | Angle of attack: FV A605 TA1/TA5
 FV A605 TA1O/TA5O
 | ¡¾30¡Æ ¡¾180¡Æ
 |   
          | Inlet opening: FV A605 TAx:
 FV A605 TAxO:
 | 9mm protecting cage
 |   
          | Sensor length: FV A605 TAx:
 FV A605 TAxO
 | 300m 310mm
 |   
          | Sensor cable length: | 1.5m |   
          | Storage temperature: | -30 to +90¡ÆC |   
          | General Technical Specifications |   
          | Measurement medium: | dry air or inert |   
          | Response time: | standard: smoothened: 1 ¥ó = 2s
 option OAA605TAU:
 not smoothened: 1 ¥ó = 100ms
 |   
          | Power supply: | through ALMEMO¢ç device (approx. 7¡¦ 10V)
 |   
          | Current consumption: | approx. 70mA |   
          | Output signal: | 0 ¡¦ 1V, linearised, load resistance min. 10kohms
 |   
          | Housing: Dimensions:
 Protection system:
 Weight:
 
 | 100 x 60 x 35mm (L x W x H) IP 40 (aluminium housing)
 approx. 250g
 |   
          | Operating temperature: | 0 to 40 |   
          | Storage temperature: | -30 to 90¡ÆC |   
          | Air humidity: | 0 ¡¦ 90% r.H., non-condensing |   
          | Adjusting reference: | laser Doppler wind tunnel, adjustment at 22¡ÆC/approx.
 960hPa, (certificate according
 to SN EN 45001)
 |  |