ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > ºÐ±¤±¤µµ°è (Spectrophotometer) > Labomed ºÐ±¤ºÐ¼®±â

 
UVD-3400 Spectro UV-Vis Double Beam ºÐ±¤ºÐ¼®±â
    ¡¤ °í°´¼±È£µµ :
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)

Spectro UV-Vis Double Beam
Research Spectophotometer
Model UVD-3400
Model UVD-3500

Spectro UV-Vis Double Beam
Research Spectophotometer
Model UVD-3400
Model UVD-3500
Spectro UV-VIS Double Beam UVD 3400 has excellent performance blazed hollographic grating optimized and optional reflactance attachment CT-type monochromator and reduces stray light and widen the photometric range.
Excellent baseline stability: recording photometric system and high stability.
High resolution: enhancement of full transmission and full reflection that both need for double beam optic and high energy to reduce noise and guarantee high resolution.
Other advantages are:
Accurate wavelength; Easy accesories replacement; Easy operation; Versatile application software and small beam size; micro and macro sample volume with high absorbance.

There are 2 models of Spectro UV-Vis Double Beam PC Research Spectrophotometer available:
1) Spectro UV-Vis Double Beam (Model UVD-3400) with fixed bandwidth of 2 nm.
2) Spectro UV-Vis Double Beam (Model UVD-3500) with variable bandwidth of
0.1, 0.2, 0.5, 1.0, 2.0 and 5.0 nm. is also available.

¡¡
Technical Specifications




1) Optical System: Double Beam
- Wavelength range: 190 nm – 900 nm
- Spectral bandwidth: 2nm (UVD-3400) and 0.1, 0.2, 0.5nm, 1.0nm, 2.0nm, and 5.0 nm.(UVD-3500).
- Stray Light: 0.015%T (220nm & 340 nm)
- Wavelength accuracy: ¡¾0.3 nm(automatic correction)
- Wavelength Reproducibility: 0.1 nm
2) Photometric System: The double-beam ratio recording system.
- Optical System: The monochromator of Czerny-Turner configuration with high-resolution diffraction holographic grating.
- Photometric Method: Transmittance, absorbance, reflectance, energy, concentration.
- Photometric Range: -4.0 ~ 4.0 Abs
- Photometric Accuracy: ¡¾0.3%T(0~100%T) ¡¾0.002Abs(0~0.5 Abs) ¡¾ 0.004Abs(0.5~1.0 Abs)
- Photometric Reproducibility: 0.001Abs(0~0.5 Abs)
- Baseline flatness: ¡¾0.001Abs
- Baseline stability: 0.0004Abs/h (500nm, after preheating)
- Absorbance Range: -9.999 to 9.999 ABS
- Continuously variable spectral bandiwth from: 0.1, 0.2, 0.5, 1.0, 2.0 and 5.0 nm.
-Scanning Speed: 1000 nm/min
-Interface Card: PC Compatible
-Detector: Hi sensivity R928 multiplier detector.
-Photometric Display: Unlimited
-Photometric Noise: <¡¾0.0003 Abs (500nm, 0Abs, 2nm Bandwith)
-Slew rate of wavelenght: 2400nm/min
   
   
   
3) DNA/RND Measurement:  
- Results Printout.  
4) Mainframe: Compact and standalone spectrophotometer mainframe
- Light Source: Socket Deuterium Lamp and Socket Tungsten Halogen Lamp.
- Sample Chamber: With accesories like two-cell sample holder and optional integrating sphere.
- Size: 587mm. x 562mm. x 260mm.
- Weight: 34 Kg.


¡¡
Features


  • Excellent Performance : The high- performance blazed holographic grating and the optimized CT-type monochromator reduce stray light, and widen the photometric range.

  • Ideal baseline stability: Double-beam dynamic feedback ratio recording photometric system coupled with reasonably designed electric control system ensures high stability of the instrument baseline.

  • High resolution: The unique optic design of full-transmission and full-reflection satisfies both needs of the double beam optic and the enhancement of the light energy of instrument so as to reduce noise and guarantees high resolution.

  • Accurate wavelength: The automatic wavelength driving system and the automatic light source interchanging system ensures wavelength accuracy and high holistic performance of instrument.

  • Easy accessories replacement: the detachable structure of the sample chamber facilitates change of a wide range of optional accessories and ensures wavelength accuracy of instrument.

  • Easy light replacement: The open-type design of light source chamber, socket deuterium lamp and socket tungsten halogen lamp facilitates light source over replacement, simplify maintenance and reduces operation error.

  • Versatile Application: The application software on Windows platform offers rich operation and data processing facilities, representing to the full the fascination of modern computer technology.

¡¡
Software Specifications

The windows software

  • Such operations as photometry measurement, spectrum measurement, quantitation measurement and kinetic measurement are offered in UV-Win Windows applications.
  • Multi-wavelenghts photometric measurement at up to 10 wavelenghts with the arithmetic calculation according to the user-entered formula.
  • Up to 10 spectra and time-course curves can be measured and recalled in memory with data-handling of arithmetic calculation, logarithmic calculation, reciprocal calculation, smooth, derivate (1st ~ 4th), Abs to/from %T conversion and peak pick.
  • Up to 24 standards can be entered and measured for the fit of calibration curve with order to 1st ~ 4th. Offered are the quantitation methods of single wavelength, two-wavelenght, coefficient two-wavelenght, three wavelength and 1st ~ 4th derivatives.
  • Kinetic measurement can monitor the changes of absorbance and transmittance against time course at 10 different wavelengths. This module allows flexibility in manipulation and data display.
  • With the Windows clipboard, the measured data and graphics can be copied to other applications software for reports. Also offered are filing functions, display functions, and others (such as auto file and repeat measure/scan etc.).
  • Performance—Perfectly designed high-performance spectrophotometer.
  • Light Source: Socket deuterium lamp an socket tungsten halogen lamp for easy replacement
    Detector: Photomultiplier tube
    Sample Chamber: With accessories like four-cell sample holder and an integrating sphere.
    Size: 587mm x 563 mm x 260 mm
    Weight: 34 kg.

¡¡
Accesories

¡¡

  • 4 Optical Glass Cells 10mm.

  • 2 Quartz Cells 10mm.

  • 1 Dust cover

  • 1 Instruction manual

  • 1 Power cable

  • 1 PC cable

 

ALSO AVAILABLE

Spectro UV-VIS Double Beam Research Spectrophotometer (Model UVD-3500)
Scanning Spectrophotometer UV-VIS Double Beam
Variable Bandwidth
Bandwidth: 0.1, 0.2, 0.5, 1.0 , 2.0 and 5 nm.

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ