| SU001
— Temperature Datalogger |
| Ambient Operating
Temperature |
-40¡ÆF to +150¡ÆF
(-40¡ÆC to +65¡ÆC) |
| Resolution |
0.1¡ÆF (0.2¡ÆC) |
| Accuracy |
+/- 2¡ÆF (1¡ÆC) |
| Capacity |
10,000 Data Samples |
| Power |
3.6 Volt Lithium
Battery (Supplied) |
| Battery Life |
3 year (Average
Use) |
|
SU003 — Dual
Temperature Datalogger
|
|
| Ambient Operating
Temperature |
+10¡ÆF to +140¡ÆF
(-12¡ÆC to +60¡ÆC) |
| Ambient Operating
Temperature (Sensors) |
-40¡ÆF to +170¡ÆF
(-40¡ÆC to +76¡ÆC) |
| Remote Temperature |
Precision sensor
with 6' long Probe (DLTP6) cable and 4" stainless steel submersible
tip, interchangeable |
| Accuracy |
+/- 2¡ÆF (1¡ÆC) |
| Resolution |
0.1¡ÆF (0.2¡ÆC) |
| Capacity |
8,000 Data Samples |
| Power |
9 Volt Alkaline
Battery (Not Included) |
| Battery Life |
1 year (Average
Use) |
|
SU002 —
Temperature Humidity Datalogger
|
| Ambient Operating
Temperature |
+32¡ÆF to +140¡ÆF
(0¡ÆC to +60¡ÆC) |
| Relative Humidity
Range |
0 to 100% |
| Relative Humidity
Accuracy |
+/-2% from 0-95% RH |
| Relative Humidity
Resolution |
0.1% |
| Temperature
Accuracy |
+/-2¡ÆF (1¡ÆC) |
| Temperature
Resolution |
0.1¡ÆF (0.2¡ÆC) |
| Capacity |
8,000 Data Samples |
| Power |
9 Volt Alkaline
Battery (Not Included) |
| Battery Life |
1 year (Average
Use) |
| SU004 —
4-20mA Datalogger |
|
| Ambient Operating |
+10¡ÆF to +150¡ÆF
(-12¡ÆC to +65¡ÆC) |
| Temperature Range |
|
| Current Resolution |
0.01ma |
| Current Accuracy |
0.05ma |
| Measurement
Capacity |
16,000 Data Points |
| Power |
9 Volt Alkaline
Battery (not included) |
| Battery Life |
1 year (Average
Use) |
|
SU014 —
Voltage Datalogger
|
| Ambient Operating
Temperature Range |
+10¡ÆF to +150¡ÆF
(-12¡ÆC to +65¡ÆC) |
| Voltage Range |
0 to 500 VAC |
| Voltage Resolution |
0.1 VAC |
| Voltage Accuracy |
+/- 1 VAC |
| Memory Capacity |
16,000 Data Samples |
| Power |
9 Volt Alkaline
Battery (Not Included) |
| Battery Life |
1 year (Average
Use) |
|
SU007 —
Pressure Datalogger
|
| Ambient Operating
Temperature Range |
+32¡ÆF to +130¡ÆF
(0¡ÆC to +35¡ÆC) |
| Pressure Range |
0 to 500 PSI |
| Pressure Resolution |
0.15 PSI |
| Pressure Accuracy |
+/- 3 PSI |
| Memory Capacity |
16,000 Data Samples |
| Power |
9 Volt Alkaline
Battery (Not Included) |
| Battery Life |
1 year (Average
Use) |
|
Event Dataloggers
|
| SU008 Range |
24 VAC to 270 VAC
(50/60 Hz.) 24 VDC to 180VDC |
| SU006 Range |
Dry Contacts from 0
to 10 Ohms |
| SU010 Range |
Illumination
Threshold Range: 18 LUX to1900 LUX +/-20% |
| SU009 Range |
Sound Threshold
Range: 40 db to 114 db @ 1Khz. +/-20% |
| Ambient Operating
Temperature Range |
+10¡ÆF to +140¡ÆF
(-12¡ÆC to 60¡ÆC) |
| Measurement
Capacity |
8,000 Event Samples |
| Power |
9 Volt Alkaline
Battery (Not Included) |
| Battery Life |
1 year (Average
Use) |
|
SU005 — AC
Current Datalogger
|
| Ambient Operating
Temperature Range |
+10¡ÆF to +150¡ÆF
(-12¡ÆC to +65¡ÆC) |
| Current Range |
0 to 300 Amps AC
using supplied clamp-on probe |
| Current Resolution |
0.1 Amp AC |
| Current Accuracy |
+/- 5% |
| Memory Capacity |
16,000 Data Samples |
| Power |
9 Volt Alkaline
Battery (Not Included) |
| Battery Life |
1 year (Average
Use) |